How can we help?
What are the operational parameters of Origin 65?
17 April 2023
Origin 65 ADCP is an innovative, flexible and high-performance device designed for customers requiring long-range current profiles from deep sites. Combining a novel and market-changing acoustic design, integrated modem, Pressure Inverted Echo Sounder (PIES) and mechanical release, and advanced software, this device revolutionises what is possible with a deep water ADCP.
Key operational parameters of the Origin 65 instrument are shown below.
Parameter | Specification |
Operating frequency | 62.5 kHz |
Maximum profiling range | 800+ m |
Minimum blanking distance | 12 m |
Minimum cell size | 120 mm |
Maximum number of cells | 2500 |
Maximum ping rate | 1 Hz (4 beams) |
Ambiguity limit | Up to ±2 m/s or 3.75 m/s user selectable |
Depth rating555 | 5,000 m operational |
See the Origin 65 datasheet for detailed features and specifications.
Contact support@sonardyne.com for more information.